= Sanbox/Outdoor Switch = Each two-node sanbox/outdoor setup has a 16 port Netgear GS716T Gigabit Smart Switch with the FQDN of sw-sbXX.orbit-lab.org (where XX is sanbox number 01-09) or sw-outXX.orbit-lab.org. On each switch ports 1-4 are reserved for CM subnet, ports 5-8 for sanbox control subnet while ports 9-12 are reserved for sanbox data subnet. Ports 13-15 are assigned to network management while port 16 is, as in the case of other Orbit switches, used for uplink. == Switch Configuration == Make sure switch is connected with port 16 to untagged port on the upstream switch. Use !SmartWizard to set up default password, location and DHCP as shown: [[Image(SmartWizard.jpg, 200px)]]. === === === === === === After configuration check VLANs setup by looking at the switch status and make sure that looks something like this (example is for sanbox 1 -> sw-sb01): === IEEE 802.1Q PVID Table === || Port || PVID || Port || PVID || Port || PVID || Port || PVID || || 01 || 3 || 02 || 3 || 03 || 3 || 04 || 3 || || 05 || 11 || 06 || 11 || 07 || 11 || 08 || 11 || || 09 || 12 || 10 || 12 || 11 || 12 || 12 || 12 || || 13 || 1 || 14 || 1 || 15 || 1 || 16 || 1 || === IEEE 802.1Q VLAN Settings === ||VLAN ID || Member Port || || ||01 || 02 || 03 || 04 || 05 || 06 || 07 || 08 || 09 || 10 || 11 || 12 || 13 || 14 || 15 || 16 || ||1 || || || || || || U U U U ||3 || U || U || U || U || || || || || || || || || || || || T T T T ||11|| || || || || U || U || U || U || || || || || T || T || T || T || ||12|| U || U || U || U || T || T || T || T || Configuration is done under the VLAN entry. Note: New switch has to be connected to the upstream switches untagged port for !SmartWizard to even see it. Once new switch is configured with VLANs the upstream switch port should be configured for propper VLAN trunkning.